Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
The service manual was a copy of the original from Wirlpool. The quality was good, all neccecary information was available including the service-codenumbers, so I could order the right part to be replaced for repair.
Downloding was no probem after the payment.
Thanks for the service!
 ;
Good,readable manual. I found other manuals that were not readable when it came to part ID, but the one downloaded from owner-manual.com was better than expected. I will do buisness with owner-manual.com again.
 ;
Service Manual that I received was very helpful to me. Thank you.
 ;
The manual is well organized and is easy to read. The chapters are following normal way to proceed.
 ;
This scanned manual is well done in that most all the pages except for one is straight and clear- the way I would do them. One page was upside down but that happens. For the money that is charged on this site you get a pretty good deal. Now with complex repairs, I still prefer to us paper manuals which I have to buy at stereomanuals but the one I got here was much less than the $45 he was charging but this is a larger than normal manual for three different units. I am a picky manual user because I have used original manuals from Sony and Teac.
Section VI Paragraphs 6- 16 to 6- 17
Model 196A
RO
Figure 6-4. Image-to-Object Change Detail
Turn on the oscilloscope graticule to full brilliance and either reduce room lighting o r place a black cloth over both your head and the camera. Adjust the oscilloscope brilliance until the trace can be easily seen on the frosted plate. NOTE
1) Due to the separation between the graticule and the oscilloscope phosphor, the square wave will now appear shorter horizontally than the graticule. This is caused by parallax (paragraph 5-5).
2) Note that the graticule will not be in focus. This is because of the poor depth of focus
j.
should be exactly 1 cm apart. I they are closer tof gether than that, more lens gaskets must be added to correct the ratio. I the lines are wider than that, f then one or more gaskets will have to be removed. In either case, steps a through k will have to be repeated until the desired ratio has been attained. n. Working through the lens access door and using
the stubby screwdriver, loosen the lens mounting
screws just enough to allow a hindered movement of
the lens- jamnut assembly. p. Move the lens until the center of the graticule lines up with the cross hairs on the plexiglass plate.
with the large lens opening (paragraph 5-8). This will have no effect on the accuracy of the following adjustment. k. Since, due to parallax, the oscilloscope presentation and the graticule as seen on theplexiglass plate will be a different horizontal size, you will have to decide whether you want the graticule o r the oscilloscope presentation to be a perfect 1-to -1 ratio. m. Measure the desired presentation with a centimeter scale. I a 1-to-1 ratio is desired, the lines f 6-4
q. Tighten the lens mounting screw evenly, working around the lens several times. 6-16. REFOCUSING. 6-17. GENERAL. The 196A Oscilloscope Camera is prefocused at the factory on a plane 3/8 inch from the camera nose, which is the standard combined thickness of the graticule, filter and cathode ray tube glass. Unless the camera has been dropped, o r a non-standard lens-to-object distance is desired, the camera should never need refocusing. An alternate 01038- 1